Name: weighing bridge load cell

◆Modl: DS

◆Capacity:10t to 40t.

Technical Parameter
Rated Load10t,15t,20t,25t,30t,40t
Sensitivity2.0000±0.001MV/V
Total Error±0.02%F.S
Creep(30minutes)±0.02%F.S
Recommended Excitation Voltage5V~18V(AC or DC)
Maximum Excitation Voltage24V(AC or DC)
Zero Balance±1%F.S
Input Impedance775±5Ω
Output Impedance700±2Ω
Insulation Impedance≥5000MΩ
Safe Overload150%F.S
Ultimate Overload200%F.S
Operating Temperature Range(-30~+70)℃
Compensated Temperature Range(-20~+60)℃
Temperature Effect On Load±0.02%F.S/10℃
Temperature Effect On Zero±0.02%F.S/10℃
ConstructionAlloy Steel
Protection ClassIP68&IP67
CitationGB/T7551-2008/OIML R60
Mode of ConnectionInput+:Red
Input-:Black
Output+:Green
Output-:White